Vendor-neutral, governed industrial/OT data tap + intelligent troubleshooting. Read (and, gated, write) PLCs, controllers, machine tools and IIoT brokers ove...
---
name: ot-aiops
description: >-
Vendor-neutral, governed industrial/OT data tap + intelligent troubleshooting.
Read (and, gated, write) PLCs, controllers, machine tools and IIoT brokers over
OPC-UA, Modbus-TCP, Siemens S7comm, Mitsubishi MC, MTConnect, MQTT/Sparkplug B,
Allen-Bradley EtherNet/IP, and EtherCAT (pysoem/SOEM) — plus cross-protocol diagnostics ("no-data"
dataflow diagnosis, ISA-18.2 alarm bad-actors, tag/historian health) and
analytics (OEE/downtime, asset inventory, OPC-UA HDA, change-of-value). Use when
the task names any industrial protocol, a PLC/SCADA/HMI/historian/CNC, an
opc.tcp:// or mqtt:// endpoint, OEE/downtime, or OT asset inventory. Routes to
the ot-aiops MCP server. Read-first; writes are MOC-gated (high risk, dry-run +
double-confirm). Do NOT use for IT/network gear, Kubernetes, hypervisors, or
backups — those are separate AIops tools.
---
# ot-aiops — industrial data tap + intelligent troubleshooting
One governed MCP server exposing **57 tools** across 8 industrial protocols plus a
cross-protocol intelligence layer. Every tool runs through the ot-aiops governance
harness (audit / budget / risk-tier / undo). **Read-first.** The 6 write tools are
gated as Management-of-Change: `risk=HIGH`, `dry_run=True` by default, CLI requires
a double-confirm, the before-value is captured for undo. **Never write to a
production control system without authorization.** Preview / mock-or-sim validated —
verify against live equipment. Start with `protocols_supported` to see what's
configured and `<protocol> doctor` to test a link.
## When to route here
Task mentions: OPC-UA / opc.tcp, Modbus, Siemens S7 / S7-1200/1500, Mitsubishi /
MELSEC, MTConnect / CNC machine monitoring, MQTT / Sparkplug B / Unified Namespace,
Allen-Bradley / ControlLogix / CompactLogix / EtherNet-IP, EtherCAT / CoE / SDO /
PDO / SOEM, OEE / downtime, OT asset inventory, "no data / stale tag" diagnosis,
alarm flood / ISA-18.2.
## Tools by protocol
### OPC-UA (read-only) — opc.tcp endpoints
- `opcua_server_info` — status, build info, namespace array
- `opcua_browse` — browse node tree from a node id (bounded depth)
- `opcua_read_node` — value + datatype + source timestamp + status code
- `opcua_read_many` — batch read node ids (bounded)
- `opcua_subscribe_sample` — bounded sampling, then returns (never loops)
- `opcua_read_alarms` — best-effort active alarm/condition surfacing
- `opcua_read_history` — Historical Access (HDA): raw history over a [start,end] window
- `health_summary` — classify node-ids vs warn/alarm thresholds
- `anomaly_scan` — sample a node, flag statistical outliers
### Modbus-TCP (read-only here)
- `modbus_read_holding` (FC03), `modbus_read_input` (FC04), `modbus_read_coils`
(FC01), `modbus_read_discrete` (FC02) — with decode hints
- `modbus_health_summary` — classify registers vs thresholds
### Siemens S7comm (pyS7; S7-300/400/1200/1500)
- `s7_cpu_info` — CPU identity + run/stop
- `s7_read_area` — read N items of a type from an S7 memory area
- `s7_read_db` — read N items from a data block
- `s7_read_many` — batch raw pyS7 address strings
- `s7_write_db` — **[WRITE][HIGH][MOC]** write one value to a DB (off by default)
### Mitsubishi MC (pymcprotocol 3E; Q/L/iQ)
- `mc_cpu_status` — MELSEC CPU type/code
- `mc_read_words` / `mc_read_bits` — batch word/bit devices from a head device
- `mc_read_many` — random-read scattered word + dword in one request
- `mc_write_words` — **[WRITE][HIGH][MOC]** write words (off by default)
### MTConnect (read-only; all CNC machine tools)
- `mtconnect_probe` — device model (devices → components → data items)
- `mtconnect_current` — latest value of every data item (machine snapshot)
- `mtconnect_sample` — bounded stream of recent observations
- `mtconnect_assets` — cutting tools / fixtures / programs
- `mtconnect_oee_snapshot` — availability / execution / mode / program (OEE inputs)
### MQTT / Sparkplug B / UNS (paho-mqtt; full Tahu protobuf decode)
- `mqtt_read_topic` — plain MQTT bounded message collect
- `sparkplug_decode_payload` — decode one raw Sparkplug B payload to metrics
- `sparkplug_subscribe_sample` — bounded sample w/ full decode + birth/death/seq
- `sparkplug_node_list` — edge nodes/devices + online state + primary-host STATE
- `uns_browse` — browse the live topic tree (UNS) under a filter (bounded)
- `mqtt_publish` — **[WRITE][HIGH][MOC]** publish/command to a topic (off by default)
### Allen-Bradley EtherNet/IP (pycomm3; ControlLogix/CompactLogix)
- `eip_controller_info` — controller identity (proves the CIP link)
- `eip_list_tags` — discover controller tag list (names/types/structures)
- `eip_read_tag` — read one tag (or array element) with its type
- `eip_read_many` — batch read (auto multi-packet)
- `eip_write_tag` — **[WRITE][HIGH][MOC]** write one tag value (off by default)
### EtherCAT (pysoem/SOEM; **Linux + root/CAP_NET_RAW + dedicated NIC + real slaves**)
Optional extra `pip install ot-aiops[ethercat]`; **no software simulator** (hardware-only,
macOS unsupported). Tools degrade to a teaching error if pysoem/permission/NIC/bus is missing.
- `ethercat_master_state` — master/working-counter state + expected vs found slave count
- `ethercat_slaves` — bus scan: enumerate slaves (id/vendor/product/rev/addr/AL-state)
- `ethercat_slave_info` — one slave: SM/FMMU config + object-dictionary summary
- `ethercat_read_sdo` — CoE SDO upload (acyclic mailbox read of an OD entry)
- `ethercat_read_pdo` — one cyclic snapshot of a slave's input process-data image
- `ethercat_write_sdo` — **[WRITE][HIGH][MOC]** CoE SDO download (off by default)
- `ethercat_set_state` — **[WRITE][HIGH][MOC]** AL-state transition (can START/STOP motion; off by default)
## Cross-protocol intelligence
### Diagnostics — `skills` umbrella: troubleshooting
- `diagnose_dataflow` — localize a "no data" break across an endpoint's reachable hops
- `historian_health` — bad-tag / flatline / gap detection over a series
- `alarm_bad_actors` — ISA-18.2 alarm-flood analysis (rate vs <6/12/30, Pareto
offenders, chattering, standing) over an event list
- `tag_health` — rank tag offenders by bad-quality / flatline / range / anomaly
### Analytics
- `oee_compute` — OEE = Availability × Performance × Quality
- `downtime_events` — detect running→stopped transitions, categorize stoppages
- `oee_multidim` — aggregate OEE across machine × part × shift
- `asset_inventory` — actively fingerprint endpoints (vendor/model/firmware/protocol)
into an asset register (active discovery, **not** passive SPAN/tap)
- `monitor_changes` — capture only the value CHANGES of a point over a bounded window
### Meta / roadmap
- `protocols_supported` — capability map (protocols, status, tools, connection params)
- Roadmap: EtherCAT EoE/FoE/SoE mailbox protocols; EtherNet/IP PLC-5 / SLC (PCCC),
Micro800; passive asset discovery; OPC-UA certificate security.
## Setup
`ot-aiops init` (interactive wizard, per-protocol prompts) writes
`~/.ot-aiops/config.yaml`; credentials go to the encrypted store
(`~/.ot-aiops/secrets.enc`, master password via `OT_AIOPS_MASTER_PASSWORD`). Run
`ot-aiops doctor` to probe each configured endpoint. Full per-protocol reference,
connection params, simulator-test guide, and MCP JSON examples are in the README.
## Safety
Read-first. The 6 write tools (`s7_write_db`, `mc_write_words`, `mqtt_publish`,
`eip_write_tag`, `ethercat_write_sdo`, `ethercat_set_state`) default to `dry_run=True`,
require a CLI double-confirm, and record an undo descriptor from the captured
before-value/state. EtherCAT state changes can START or STOP machine motion. Do not
point this at production control systems without authorization. No tool returns secrets.