Read OPC-UA servers (opc.tcp) — browse the node tree, read node values with datatype/timestamp/status, bounded sampling, server info, best-effort alarm/condi...
---
name: opcua-tap
description: >-
Read OPC-UA servers (opc.tcp) — browse the node tree, read node values with
datatype/timestamp/status, bounded sampling, server info, best-effort
alarm/condition surfacing, and threshold/anomaly health. Use when the task
names OPC-UA, an opc.tcp:// endpoint, or a SCADA/PLC gateway exposing OPC-UA.
Routes to the ot-aiops MCP server. Read-only. Do NOT use for IT/network gear,
Kubernetes, hypervisors, or backups; for Modbus/S7/Mitsubishi/MTConnect/MQTT
use the sibling *-tap skills.
---
# opcua-tap
Read-only OPC-UA telemetry + problem surfacing via the **ot-aiops** MCP server.
Preview — validated against an in-process asyncua simulator, NOT live SCADA.
## When to use
- An OPC-UA server / PLC gateway (`opc.tcp://host:4840`), anonymous or user/pass.
- Discover the address space, read tags, sample a node, surface alarms.
## When NOT to use (routing)
- Modbus → `modbus-tap`; Siemens S7 → `s7-tap`; Mitsubishi → `mc-tap`; CNC
machine tools → `mtconnect-tap`; MQTT/Sparkplug/UNS → `sparkplug-tap`;
Rockwell/Allen-Bradley EtherNet/IP → `ethernetip-tap`.
- Cross-protocol "why no data" / alarm-flood / tag-health → `industrial-diagnostics`;
OEE / downtime / asset inventory → `industrial-analytics`.
- IT/network devices, Kubernetes, hypervisors, backups → not this tool.
## Tools
| Tool | Params | Returns |
|------|--------|---------|
| `opcua_server_info` | `endpoint?` | `{state, product_name, namespaces[...]}` |
| `opcua_browse` | `node_id="i=85", endpoint?, depth=2` | `[{node_id, browse_name, node_class, depth, parent}]` |
| `opcua_read_node` | `node_id, endpoint?` | `{value, datatype, source_timestamp, status_code, good}` |
| `opcua_read_many` | `node_ids[], endpoint?` | `[{node_id, value, ...}]` |
| `opcua_subscribe_sample` | `node_id, endpoint?, samples=5, interval_ms=500, timeout_s=30` | `{collected, samples[...]}` (bounded) |
| `opcua_read_alarms` | `endpoint?, node_id="i=85", depth=4` | `{active_alarms[...], active_count}` |
| `opcua_read_history` | `node_id, endpoint?, start?, end?, max_points=1000` | `{supported, count, values:[{value, source_timestamp, status_code}]}` |
| `health_summary` | `endpoint?, node_ids[]?, thresholds?` | `{overall, counts, offenders[...]}` |
| `anomaly_scan` | `node_id, endpoint?, samples=20, interval_ms=200, sigma=3.0` | `{mean, stddev, outliers[...]}` |
`opcua_read_history` is OPC-UA **Historical Access (HDA)**: raw historical values
over a `[start,end]` ISO-8601 window (bounded). It returns `{supported:false, note}`
gracefully when the server does not historize the node. For bounded change-of-value
(only the changes, not every sample) use `monitor_changes` from `industrial-analytics`.
## Example
`opcua_read_node(node_id="ns=2;i=5", endpoint="line1")`
→ `{"value":85.0,"datatype":"Double","source_timestamp":"2026-06-28T10:00:00Z","good":true}`
## Setup
`ot-aiops init` (add an opcua endpoint) · `ot-aiops doctor` · `ot-aiops mcp`.
Config: `~/.ot-aiops/config.yaml`; secrets encrypted in `secrets.enc`, unlocked
via `OT_AIOPS_MASTER_PASSWORD`.
## Safety
Read-only. Cert/message security (Sign/Encrypt) is roadmap — only anonymous +
user/pass are validated. Endpoint text is sanitized; secrets are never returned.
Missing a feature? 缺功能提 issue/PR 欢迎留言.