Vendor-neutral, governed industrial/OT data tap + intelligent troubleshooting. Read (and, gated, write) PLCs, controllers, machine tools and IIoT brokers ove...
---
name: iaiops
description: >-
Vendor-neutral, governed industrial/OT data tap + intelligent troubleshooting.
Read (and, gated, write) PLCs, controllers, machine tools and IIoT brokers over
OPC-UA, Modbus-TCP, Siemens S7comm, Mitsubishi MC, MTConnect, MQTT/Sparkplug B,
Allen-Bradley EtherNet/IP, EtherCAT (pysoem/SOEM), SECS/GEM (semiconductor /
display fab equipment over HSMS), PROFINET (DCP discovery), and the energy
edition (IEC 60870-5-104, DNP3, IEC 61850 MMS) — plus cross-protocol diagnostics
("no-data" dataflow diagnosis, OPC-UA connection self-diagnosis, subscription
health, ISA-18.2 alarm bad-actors, tag/historian health, and the AI downtime
root-cause copilot) and analytics (OEE/downtime, asset inventory, OPC-UA HDA,
change-of-value). Use when the task names any industrial protocol, a
PLC/SCADA/HMI/historian/CNC/RTU/IED, a semiconductor/display fab or SECS/GEM
equipment, an electrical substation, an opc.tcp:// or mqtt:// endpoint,
OEE/downtime, downtime root-cause, or OT asset inventory. Routes to
the iaiops MCP server. Read-first; writes are MOC-gated (high risk, dry-run +
double-confirm). Do NOT use for IT/network gear, Kubernetes, hypervisors, or
backups — those are separate AIops tools.
---
# iaiops — industrial data tap + intelligent troubleshooting
One governed MCP server exposing **90 tools** across 14 industrial protocols plus a
cross-protocol intelligence layer. Narrow the exposed surface per site with
`IAIOPS_MCP` (e.g. `IAIOPS_MCP=fab` or `IAIOPS_MCP=opcua,modbus`), or just launch the matching pre-scoped
script (`iaiops-mcp-opcua`, `iaiops-mcp-fab`, … — sugar over `IAIOPS_MCP`). Every tool runs through the iaiops governance
harness (audit / budget / risk-tier / undo). **Read-first.** The 6 write tools are
gated as Management-of-Change: `risk=HIGH`, `dry_run=True` by default, CLI requires
a double-confirm, the before-value is captured for undo. **Never write to a
production control system without authorization.** Preview / mock-or-sim validated —
verify against live equipment. Start with `protocols_supported` to see what's
configured and `<protocol> doctor` to test a link.
## When to route here
Task mentions: OPC-UA / opc.tcp, Modbus, Siemens S7 / S7-1200/1500, Mitsubishi /
MELSEC, MTConnect / CNC machine monitoring, MQTT / Sparkplug B / Unified Namespace,
Allen-Bradley / ControlLogix / CompactLogix / EtherNet-IP, EtherCAT / CoE / SDO /
PDO / SOEM, SECS/GEM / SECS-II / HSMS / semiconductor / display fab / wafer / panel
/ MES equipment / SVID / ECID, PROFINET / DCP / name-of-station, IEC 60870-5-104 /
IEC-104 / RTU / telecontrol, DNP3 / outstation, IEC 61850 / MMS / IED / substation,
energy / power / utility SCADA, BACnet / BACnet-IP / building automation / HVAC /
facility / 厂务 / Who-Is, OEE / downtime, OT asset inventory, "no data / stale
tag" diagnosis, **downtime root-cause / why did the line stop**, OPC-UA "won't
connect", subscription drops, alarm flood / ISA-18.2.
## Tools by protocol
### OPC-UA (read-only) — opc.tcp endpoints
- `opcua_server_info` — status, build info, namespace array
- `opcua_browse` — browse node tree from a node id (bounded depth)
- `opcua_read_node` — value + datatype + source timestamp + status code
- `opcua_read_many` — batch read node ids (bounded)
- `opcua_subscribe_sample` — bounded sampling, then returns (never loops)
- `opcua_read_alarms` — best-effort active alarm/condition surfacing
- `opcua_read_history` — Historical Access (HDA): raw history over a [start,end] window
- `opcua_diagnose_connection` — classify *why* a connect fails (certificate / security
policy / auth / firewall / dns / port / config) with the exact fix, not a raw error
- `health_summary` — classify node-ids vs warn/alarm thresholds
- `anomaly_scan` — sample a node, flag statistical outliers
### Modbus-TCP (read-only here)
- `modbus_read_holding` (FC03), `modbus_read_input` (FC04), `modbus_read_coils`
(FC01), `modbus_read_discrete` (FC02) — with decode hints
- `modbus_health_summary` — classify registers vs thresholds
### Siemens S7comm (pyS7; S7-300/400/1200/1500)
- `s7_cpu_info` — CPU identity + run/stop
- `s7_read_area` — read N items of a type from an S7 memory area
- `s7_read_db` — read N items from a data block
- `s7_read_many` — batch raw pyS7 address strings
- `s7_write_db` — **[WRITE][HIGH][MOC]** write one value to a DB (off by default)
### Mitsubishi MC (pymcprotocol 3E; Q/L/iQ)
- `mc_cpu_status` — MELSEC CPU type/code
- `mc_read_words` / `mc_read_bits` — batch word/bit devices from a head device
- `mc_read_many` — random-read scattered word + dword in one request
- `mc_write_words` — **[WRITE][HIGH][MOC]** write words (off by default)
### MTConnect (read-only; all CNC machine tools)
- `mtconnect_probe` — device model (devices → components → data items)
- `mtconnect_current` — latest value of every data item (machine snapshot)
- `mtconnect_sample` — bounded stream of recent observations
- `mtconnect_assets` — cutting tools / fixtures / programs
- `mtconnect_oee_snapshot` — availability / execution / mode / program (OEE inputs)
### MQTT / Sparkplug B / UNS (paho-mqtt; full Tahu protobuf decode)
- `mqtt_read_topic` — plain MQTT bounded message collect
- `sparkplug_decode_payload` — decode one raw Sparkplug B payload to metrics
- `sparkplug_subscribe_sample` — bounded sample w/ full decode + birth/death/seq
- `sparkplug_node_list` — edge nodes/devices + online state + primary-host STATE
- `uns_browse` — browse the live topic tree (UNS) under a filter (bounded)
- `mqtt_publish` — **[WRITE][HIGH][MOC]** publish/command to a topic (off by default)
### Allen-Bradley EtherNet/IP (pycomm3; ControlLogix/CompactLogix)
- `eip_controller_info` — controller identity (proves the CIP link)
- `eip_list_tags` — discover controller tag list (names/types/structures)
- `eip_read_tag` — read one tag (or array element) with its type
- `eip_read_many` — batch read (auto multi-packet)
- `eip_write_tag` — **[WRITE][HIGH][MOC]** write one tag value (off by default)
### EtherCAT (pysoem/SOEM; **Linux + root/CAP_NET_RAW + dedicated NIC + real slaves**)
Optional extra `pip install iaiops[ethercat]`; **no software simulator** (hardware-only,
macOS unsupported). Tools degrade to a teaching error if pysoem/permission/NIC/bus is missing.
- `ethercat_master_state` — master/working-counter state + expected vs found slave count
- `ethercat_slaves` — bus scan: enumerate slaves (id/vendor/product/rev/addr/AL-state)
- `ethercat_slave_info` — one slave: SM/FMMU config + object-dictionary summary
- `ethercat_read_sdo` — CoE SDO upload (acyclic mailbox read of an OD entry)
- `ethercat_read_pdo` — one cyclic snapshot of a slave's input process-data image
- `ethercat_write_sdo` — **[WRITE][HIGH][MOC]** CoE SDO download (off by default)
- `ethercat_set_state` — **[WRITE][HIGH][MOC]** AL-state transition (can START/STOP motion; off by default)
### SECS/GEM (read-only; semiconductor / display fab equipment ↔ host over HSMS)
Optional extra `pip install iaiops[secsgem]` (or the `iaiops[fab]` bundle). We are the
HOST (HSMS ACTIVE). SECS/GEM (SEMI E5 SECS-II · E30 GEM · E37 HSMS) is the fab equipment
↔ MES standard — the entry ticket for panel/semiconductor fabs.
- `secsgem_equipment_status` — establish the GEM link + Are-You-There (S1F1/F2)
- `secsgem_list_status_variables` — SVID namelist (S1F11/F12)
- `secsgem_read_status_variables` — SVID values (S1F3/F4)
- `secsgem_list_equipment_constants` — ECID namelist (S2F29/F30)
- `secsgem_read_equipment_constants` — ECID values (S2F13/F14)
- `secsgem_list_alarms` — alarm list (S5F5/F6): ALID, ALCD, text
- `secsgem_list_process_programs` — PPID directory (S7F19/F20)
> **Fab routing (semiconductor / display, e.g. panel TFT-LCD/OLED).** A fab equipment
> is two layers: its **internal control** (PLC over S7 / OPC-UA / Modbus) and its
> **MES-facing** SECS/GEM (HSMS) interface — different jobs, don't conflate. Use
> `IAIOPS_MCP=fab` (secsgem + opcua + s7 + modbus). Read-first: `secsgem_equipment_status`
> to confirm the link, then SVID/ECID/alarms; the PLC layer via the S7/OPC-UA tools.
### PROFINET (read-only DCP discovery; pnio-dcp, layer-2 raw socket)
Optional extra `pip install iaiops[profinet]` (or the `iaiops[factory]` bundle). Needs
raw-socket access (root/admin/CAP_NET_RAW) on the NIC on the PROFINET subnet; `host` is
THIS machine's IP on that subnet. **Discovery + identify only** — no RT cyclic data, no
disruptive DCP Set (set-name/ip/blink/reset).
- `profinet_discover` — DCP IdentifyAll: every station on the segment (name/MAC/IP/role)
- `profinet_identify_station` — identify one station by its name-of-station
- `profinet_station_params` — targeted DCP Get by MAC (name + IP suite)
- `profinet_asset_inventory` — register with IO-controller vs IO-device role decoding
### Energy edition (read-only; electrical substation / utility telecontrol)
Optional bundle `pip install iaiops[energy]` and `IAIOPS_MCP=energy`. **Monitor direction
only** — no control commands. **⚠️ Preview / 待核实**: library bindings are mock-tested,
not verified against live RTUs/IEDs (`iec61850` needs libiec61850 built).
- **IEC 60870-5-104** (`iaiops[iec104]`): `iec104_connection_info` (link + ASDU CAs),
`iec104_interrogate` (general interrogation), `iec104_read_point` (one point by IOA)
- **DNP3** (`iaiops[dnp3]`): `dnp3_link_status`, `dnp3_integrity_poll` (Class 0/1/2/3 →
outstation database grouped by binary/analog/counter)
- **IEC 61850 MMS** (`iaiops[iec61850]`): `iec61850_device_directory` (model map),
`iec61850_browse` (LD/LN/DO children), `iec61850_read` (object-ref + functional constraint)
### Building edition (read-only; facility / HVAC / 厂务 — BACnet/IP)
Optional bundle `pip install iaiops[building]` and `IAIOPS_MCP=building`. `host` is THIS
machine's BACnet/IP interface (`ip` or `ip/mask`). **Read-only** — no building-control
writes. **⚠️ Preview / 待核实**: BAC0 binding not verified against live gear.
- `bacnet_discover` — Who-Is: devices on the local BACnet/IP network
- `bacnet_object_list` — a device's object/point list
- `bacnet_read_property` — one object property (default presentValue)
- `bacnet_read_points` — presentValue of all analog/binary/multistate points (HVAC snapshot)
## Cross-protocol intelligence
### Diagnostics — `skills` umbrella: troubleshooting
- `diagnose_dataflow` — localize a "no data" break across an endpoint's reachable hops
- `downtime_root_cause` — **AI downtime root-cause copilot (flagship)**: correlate alarms /
tags / dataflow / machine-state around an incident window into an evidence-cited,
**advisory** verdict (read-only; cites only real signals; `insufficient_evidence` over
guessing). `downtime_root_cause_live` gathers the evidence itself from an endpoint.
- `historian_health` — bad-tag / flatline / gap detection over a series
- `alarm_bad_actors` — ISA-18.2 alarm-flood analysis (rate vs <6/12/30, Pareto
offenders, chattering, standing) over an event list
- `tag_health` — rank tag offenders by bad-quality / flatline / range / anomaly
- `subscription_health` — sequenced-feed loss/reorder/overload (OPC-UA monitored items
or Sparkplug B): sequence gaps, republish-rejection rate, overloaded channels
- `data_quality_scorecard` — fleet data-TRUST rollup: scores each tag 0-100 on staleness /
dead heartbeat / bad-quality / flatline / gaps / anomaly, per endpoint + fleet
- `heartbeat_health` — first-class heartbeat/watchdog liveness (flatline = dead upstream)
- `uns_topic_audit` — UNS naming conformance + topic-sprawl governance (casing collisions,
scattered leaves, depth outliers, duplicates → clean/minor/sprawling)
- `uns_schema_drift` — Sparkplug schema drift baseline-vs-current → none/additive/breaking
### Analytics
- `oee_compute` — OEE = Availability × Performance × Quality
- `downtime_events` — detect running→stopped transitions, categorize stoppages
- `oee_multidim` — aggregate OEE across machine × part × shift
- `asset_inventory` — actively fingerprint endpoints (vendor/model/firmware/protocol)
into an asset register (active discovery, **not** passive SPAN/tap)
- `monitor_changes` — capture only the value CHANGES of a point over a bounded window
### 信创 / China entry + compliance
- `compliance_mapping` — 《工控系统网络安全防护指南》 ↔ iaiops governance self-assessment
(分区隔离 / 可审计 / 双向认证 / 最小权限 / 数据保护 / 自主可控) with honest status + gaps
- `historian_push` — write collected telemetry to a domestic TSDB (TDengine / IoTDB);
data egress to the operator's own historian, not a control write. See docs/CHINA.md
for air-gapped install + 国产 OS/芯/PLC validation matrix (待核实).
### Meta / roadmap
- `protocols_supported` — capability map (protocols, status, tools, connection params)
- Roadmap: EtherCAT EoE/FoE/SoE mailbox protocols; EtherNet/IP PLC-5 / SLC (PCCC),
Micro800; passive asset discovery; OPC-UA certificate security.
## Setup
`iaiops init` (interactive wizard, per-protocol prompts) writes
`~/.iaiops/config.yaml`; credentials go to the encrypted store
(`~/.iaiops/secrets.enc`, master password via `IAIOPS_MASTER_PASSWORD`). Run
`iaiops doctor` to probe each configured endpoint. Full per-protocol reference,
connection params, simulator-test guide, and MCP JSON examples are in the README.
## Safety
Read-first. The 6 write tools (`s7_write_db`, `mc_write_words`, `mqtt_publish`,
`eip_write_tag`, `ethercat_write_sdo`, `ethercat_set_state`) default to `dry_run=True`,
require a CLI double-confirm, and record an undo descriptor from the captured
before-value/state. EtherCAT state changes can START or STOP machine motion. Do not
point this at production control systems without authorization. No tool returns secrets.